hes 9400 electric strike pdf

PDF Nov 17, 2024

The HES 9400 Electric Strike is a surface-mounted solution designed for rim exit devices, offering field-selectable operation modes, voltage options, and an included spacer plate for easy installation․

1․1 Overview of the HES 9400 Series

The HES 9400 Series is a sleek, surface-mounted electric strike designed for compatibility with rim exit devices featuring a 1/2″ Pullman latchbolt․ Known for its slim-line design, it is ideal for both metal and wood door frames, requiring no frame cutting for installation․ The series includes a 1/8″ spacer plate to accommodate varying door gaps and offers durable construction with multiple finish options․ Its compact design and robust performance make it a versatile solution for secure and reliable door control systems․

1․2 Importance of the HES 9400 in Door Security Systems

The HES 9400 Electric Strike plays a pivotal role in door security systems by providing a reliable and durable solution for access control․ Its Grade 1 certification ensures superior strength and performance, making it suitable for high-security applications․ The ability to operate in both fail-safe and fail-secure modes offers flexibility for different security needs․ Additionally, its compatibility with rim exit devices and included spacer plate for door gap adjustment enhance its versatility, making it a critical component for ensuring secure and efficient door operations in various environments․

Product Features and Specifications

The HES 9400 Electric Strike offers Grade 1 strength, field-selectable operation modes, and voltage options, ensuring reliability and durability for secure door systems․

2․1 Grade 1 Strength and Performance

The HES 9400 surpasses Grade 1 standards, ensuring exceptional strength and durability․ Its robust construction handles heavy traffic and harsh environments, making it ideal for high-security applications․ The strike’s performance is consistent and reliable, providing smooth operation and long-lasting durability․ This ensures it meets the demands of commercial and industrial settings, offering a secure solution for various door systems․

2․2 Field-Selectable Operation Modes (Fail Safe/Fail Secure)

The HES 9400 offers field-selectable operation modes, allowing users to choose between fail-safe and fail-secure functionality․ Fail-secure mode keeps the strike locked when power is lost, enhancing security, while fail-safe mode unlocks the strike, ensuring safe egress in emergencies․ This flexibility makes it suitable for various applications, including fire-rated doors where fail-safe operation is often required․ The mode can be easily set during installation, providing adaptability to meet specific security needs without compromising performance or safety standards․

2․3 Voltage Options (12VDC and 24VDC)

The HES 9400 Electric Strike supports both 12VDC and 24VDC voltage options, offering flexibility for various power supply requirements․ This dual voltage capability ensures compatibility with different systems and simplifies installation․ The strike operates efficiently across both voltages, providing consistent performance․ The voltage selection is made during setup, allowing users to choose the appropriate power source based on their specific application needs․ This feature enhances adaptability, making the HES 9400 suitable for a wide range of commercial and industrial environments․

2․4 Surface-Mounted Design for Easy Installation

The HES 9400 Electric Strike features a surface-mounted design, eliminating the need for frame cutting and simplifying installation․ This design accommodates both metal and wood door frames, offering versatility for various applications․ The strike aligns effortlessly with the exit latchbolt, ensuring proper engagement and functionality․ A 1/8-inch spacer plate is included to adjust for door gaps, further enhancing installation ease․ This streamlined design reduces labor and ensures a secure, professional-grade setup for commercial or industrial environments․

2․5 Compatibility with Rim Exit Devices

The HES 9400 Electric Strike is specifically designed to work with rim exit devices, ensuring compatibility with latchbolts up to 1/2″ Pullman․ This feature enhances functionality and security, accommodating various door configurations․ The strike’s design allows for seamless integration with standard rim exit hardware, providing reliable operation and durability․ Its compatibility ensures smooth interaction between the latchbolt and strike, maintaining proper clearance and engagement for consistent performance in high-traffic environments․

2․6 Included Spacer Plate for Door Gap Adjustment

The HES 9400 Electric Strike includes a 1/8″ spacer plate to accommodate varying door gaps, ensuring proper alignment and engagement with the latchbolt․ This feature simplifies installation by allowing adjustability for different door configurations․ The spacer plate is pre-installed, but additional plates can be ordered if further adjustments are needed․ This design ensures consistent performance and security across diverse door setups, making it a versatile solution for various applications․

2․7 Durable Construction and Finish Options

The HES 9400 Electric Strike features a robust construction with a Grade 1 rating, ensuring exceptional strength and reliability․ It is available in multiple finishes, including stainless steel for the 630 finish and black stainless steel for other options, providing durability and aesthetic versatility․ The smooth cover design conceals mounting screws, offering a sleek and professional appearance while maintaining long-lasting performance in various environments․

Installation Requirements and Preparation

The HES 9400 requires proper frame preparation and alignment with the latchbolt for secure mounting․ It includes a spacer plate for door gap adjustment, ensuring precise installation․

3․1 Tools and Materials Needed

For installing the HES 9400 Electric Strike, you’ll need a Phillips screwdriver, 1/4-20 x 1 mounting screws, a drill, and a 1/8-inch spacer plate․ Additional tools may include a wrench, pliers, and a wire stripper for electrical connections․ Ensure you have the correct wire gauge for your voltage and distance requirements․ The strike ships with a spacer plate to accommodate door gaps, but extra plates can be ordered if needed․ Always refer to the installation manual for specific requirements and safety guidelines․

3․2 Frame Preparation for Electric Strike Installation

Prepare the door frame by ensuring it’s clean and free of debris․ Align the strike with the latchbolt, using the provided template for accurate placement․ For metal frames, ensure screws are properly seated, while wood frames may require pre-drilling to avoid splitting․ The HES 9400’s surface-mounted design eliminates the need for frame cutting, making installation straightforward․ Secure the strike firmly to maintain proper latchbolt engagement and ensure smooth operation․

3․3 Mounting the Electric Strike on the Door Frame

Mount the HES 9400 Electric Strike by aligning it with the exit latchbolt on the door frame․ Secure it using the provided 1/4-20 x 1 mounting screws․ The strike’s surface-mounted design ensures easy installation without frame cutting․ Ensure the strike is tightly fastened to maintain proper latchbolt engagement․ For varying door gaps, the included 1/8 spacer plate can be used․ This process works for both metal and wood frames, providing a sturdy and reliable installation․

3․4 Aligning the Strike with the Latchbolt

Align the HES 9400 Electric Strike with the exit latchbolt on the door frame․ Ensure the strike’s keeper is properly positioned to interact with the latchbolt for smooth operation․ If necessary, adjust the horizontal alignment using the provided spacer plate to accommodate varying door gaps․ Proper alignment ensures secure engagement and prevents wear on the latchbolt․ Once aligned, secure the strike firmly to maintain precise functionality and reliable door operation․

3․5 Securing the Strike with Mounting Screws

Use the provided 1/4-20 x 1 mounting screws to secure the HES 9400 Electric Strike to the door frame․ Tighten the screws firmly to prevent any movement during operation․ Ensure the screws are evenly tightened to maintain proper alignment with the latchbolt․ Avoid overtightening, as this may damage the strike or frame․ Properly secured screws ensure reliable functionality and long-term durability of the electric strike, preventing wear and tear from repeated use․

Electrical Wiring and Connections

Refer to the wiring diagram for proper connections․ The HES 9400 supports 12VDC and 24VDC, with minimum wire gauge requirements based on voltage and distance․ Connect the solenoid to the power source, ensuring correct polarity․ Verify operation mode (fail secure or fail safe) and integrate with accessories like the Latchbolt Strike Monitor (LBSM) if required․ Proper wiring ensures reliable performance and safety․

4․1 Understanding the Wiring Diagram

The wiring diagram for the HES 9400 provides a clear visual guide for connecting the solenoid, power source, and optional accessories․ It specifies voltage requirements (12VDC or 24VDC) and wire gauge recommendations based on distance․ Color-coded wires indicate positive and negative connections․ The diagram also illustrates how to integrate the Latchbolt Strike Monitor (LBSM) for advanced functionality․ Proper understanding ensures safe and correct electrical connections, avoiding polarity issues․ Refer to the diagram for fail secure and fail safe mode configurations, and note any specific warnings for fire-rated applications․

4․2 Minimum Wire Gauge Requirements

The HES 9400 requires specific wire gauges to ensure reliable operation․ For 12VDC, use 18 AWG for up to 200 feet, 16 AWG for 200-300 feet, and 14 AWG for over 300 feet․ For 24VDC, 18 AWG is suitable for up to 200 feet, 16 AWG for 200-300 feet, and 14 AWG beyond 300 feet․ Proper wire sizing prevents voltage drop and overheating, ensuring optimal performance․ Refer to the wiring diagram for detailed specifications and connections․

4․3 Connecting the Solenoid to the Power Source

Connect the solenoid to a 12VDC or 24VDC power source using the appropriate wiring․ Ensure the positive (red) and negative (black) wires are correctly attached to the solenoid terminals․ Use the Plug-In Connector for a secure and efficient connection․ Refer to the wiring diagram for specific instructions to avoid misconnections․ Proper wiring ensures smooth operation and prevents voltage drop or overheating․ Always follow safety guidelines when working with electrical components to maintain system integrity and performance․

4․4 Fail Secure vs․ Fail Safe Operation Modes

The HES 9400 Electric Strike is field-selectable between Fail Secure and Fail Safe operation modes․ Fail Secure mode keeps the strike locked during power failures, ensuring security․ Fail Safe mode unlocks when power is lost, prioritizing safety․ The default setting is Fail Secure, but users can switch modes based on application needs․ Fail Safe should not be used in fire or windstorm-rated applications, as it may compromise safety requirements․ Proper mode selection is critical for maintaining security and compliance with building standards․ Always refer to the manual for conversion instructions․

4․5 Latchbolt Strike Monitor (LBSM) Integration

The HES 9400 Electric Strike supports integration with the Latchbolt Strike Monitor (LBSM), enabling real-time monitoring of the latchbolt’s engagement status․ This feature enhances security by providing feedback to access control systems․ For proper LBSM integration, refer to the wiring diagrams in the manual, specifically Diagrams 3 and 4․ The LBSM ensures accurate status reporting, which is critical for secure door control and monitoring applications․ Proper installation and wiring are essential to maintain reliable functionality and system integrity․

Operation and Functionality

The HES 9400 Electric Strike operates smoothly, featuring a sleek cover to conceal mounting screws․ It is surface-mounted, field-selectable for fail-safe or fail-secure modes, and accommodates varying door gaps with an included spacer plate․

5․1 Verifying the Operation Mode

The HES 9400 Electric Strike is pre-set for FAIL SECURE operation but can be converted to FAIL SAFE if required․ To verify the mode, check the default setting or refer to the wiring diagrams on page 3․ The strike features red and green LEDs to indicate operation status, ensuring easy verification․ Note that FAIL SAFE mode should not be used in fire-rated or windstorm applications․ Always consult the manual for specific instructions on mode conversion and wiring connections to ensure proper functionality and safety․

5․2 Smooth Operation and Quiet Performance

The HES 9400 ensures smooth and quiet operation, enhancing user experience․ Its design minimizes noise during latchbolt engagement and release, making it suitable for various environments․ The electric strike’s durable construction and precise engineering contribute to its reliable performance․ Proper alignment and installation, as outlined in the manual, are key to maintaining its quiet and efficient functionality․ This ensures consistent operation across different door systems, providing long-term durability and satisfaction․

5․3 Adjusting the Horizontal Alignment

The HES 9400 allows for easy horizontal alignment adjustment to ensure proper latchbolt engagement․ By loosening the mounting screws, the strike can be shifted horizontally to align with the latchbolt․ Once aligned, secure the strike using the provided screws․ Proper alignment is critical for smooth operation and durability․ The included spacer plate helps accommodate varying door gaps, ensuring a precise fit․ Follow the installation instructions for optimal adjustment and performance․ This feature enhances reliability and ensures long-term functionality of the electric strike․

5․4 Ensuring Proper Latchbolt Engagement

Proper latchbolt engagement is crucial for the HES 9400’s functionality․ Ensure the strike is aligned correctly with the latchbolt to avoid obstruction․ Adjust the horizontal alignment if necessary, using the provided spacer plate to accommodate door gaps․ Secure the strike firmly with mounting screws, then test the latchbolt engagement by cycling the door․ Proper engagement ensures smooth operation, prevents wear, and maintains security․ Refer to the manual for detailed adjustment steps to guarantee optimal performance and longevity of the electric strike․ This step is essential for reliable door security․

Maintenance and Troubleshooting

Regularly inspect the HES 9400 for dust or debris and ensure proper alignment․ Check electrical connections and verify operation modes․ Address issues promptly for optimal performance․

6․1 Routine Maintenance Tips

  • Regularly inspect electrical connections to ensure they are secure and free from damage or corrosion․
  • Clean the strike and surrounding areas to remove dust, dirt, or debris that may affect performance;
  • Lubricate moving parts periodically to maintain smooth operation and prevent wear․
  • Check the alignment of the latchbolt with the strike to ensure proper engagement and adjust if necessary․
  • Replace any worn or damaged components, such as the solenoid or spacer plate, to maintain reliability․
  • Monitor the operation mode (fail secure or fail safe) to ensure it matches the application requirements․

These routine checks help extend the lifespan and ensure consistent functionality of the HES 9400 Electric Strike․

6․2 Common Issues and Solutions

  • Misaligned Latchbolt: If the latchbolt does not engage properly, adjust the horizontal alignment using the provided adjustment screws․
  • Power Issues: Check wiring connections and ensure the correct voltage (12VDC or 24VDC) is supplied to the strike․
  • Noisy Operation: Lubricate moving parts and ensure the strike is free from debris․
  • Failed Operation: Verify the operation mode (fail secure or fail safe) matches the application requirements․
  • Worn Parts: Inspect and replace components like the solenoid or spacer plate if they show signs of wear․

Addressing these common issues promptly ensures reliable performance and extends the lifespan of the HES 9400 Electric Strike․

6․3 Replacing Wearable Parts

To maintain optimal performance, it’s crucial to replace wearable parts on the HES 9400 Electric Strike as needed․ Common wearable parts include the solenoid, keeper plate, and spacer plate․ Start by disconnecting the power supply for safety․ Use the provided tools or a screwdriver to remove the mounting screws and access the internal components․ Replace the worn parts with genuine HES components to ensure compatibility and reliability․ After installation, reconnect the power and test the strike’s operation to ensure proper alignment and function․ Regular replacement of wearable parts prevents operational issues and extends the product’s lifespan․

6․4 Solenoid Replacement Procedure

To replace the solenoid in the HES 9400 Electric Strike, first disconnect the power supply to ensure safety․ Remove the mounting screws to access the internal components․ Carefully pull out the old solenoid and install the new one, ensuring proper alignment with the strike housing․ Reassemble the unit and tighten the screws securely․ Finally, reconnect the power and test the strike’s operation to confirm smooth functionality․ Always use genuine HES replacement parts to maintain performance and reliability․

Compliance and Certifications

The HES 9400 meets Grade 1 standards, ensuring robust security and durability․ It is suitable for fire-rated applications and complies with industry standards for electric strikes․

7․1 Fire-Rated Applications Considerations

The HES 9400 Electric Strike is suitable for fire-rated applications when properly installed and maintained․ It meets necessary safety standards for fire doors, ensuring compliance with regulations like NFPA 80․ The strike’s durable construction and secure operation make it ideal for such critical environments․ Proper alignment with the latchbolt and frame preparation are essential to maintain fire rating integrity․ Regular inspections and maintenance are recommended to uphold its performance in fire-rated settings․

7․2 Windstorm-Rated Applications Guidelines

The HES 9400 Electric Strike is designed to meet windstorm-related challenges, ensuring secure and reliable operation in harsh weather conditions․ Its durable construction and secure mounting features make it suitable for windstorm-rated applications․ Proper installation, including alignment and mounting, is critical to maintaining performance under extreme weather conditions․ The strike’s outdoor-rated design ensures resistance to environmental factors, making it a reliable choice for doors exposed to high winds․ Adherence to manufacturer guidelines is essential for optimal functionality in such scenarios․

7․3 Compliance with Industry Standards

The HES 9400 Electric Strike complies with industry standards for strength, performance, and safety․ It exceeds Grade 1 standards, ensuring durability and reliability in demanding environments․ The strike is UL-listed and meets BHMA criteria, demonstrating adherence to rigorous testing protocols․ Its design aligns with fire-rated and windstorm-rated application requirements, making it a versatile solution for various security needs․ Compliance with these standards ensures the product’s performance, safety, and compatibility with industry expectations, providing users with a trusted and reliable security solution;

Accessories and Optional Components

  • Additional spacer plates for door gap adjustments․
  • Blade stop for secure installation (sold separately)․
  • Plug-in connector for simplified wiring processes․

8․1 Additional Spacer Plates

The HES 9400 Electric Strike includes a 1/8″ spacer plate to accommodate varying door gaps․ Additional spacer plates can be ordered separately to provide extra flexibility during installation․ These plates are designed to maintain proper alignment and ensure smooth operation of the electric strike․ They are available in different thicknesses to suit specific installation needs․ Made from durable materials, these spacers are compatible with the HES 9400’s finish options, ensuring a seamless and professional installation․ They are ideal for addressing unique door frame conditions․

8․2 Blade Stop for Secure Installation

The HES 9400 Electric Strike supports the use of an optional blade stop (HES 9000-ASB) for enhanced security and stability․ This accessory ensures the strike remains securely in place, preventing tampering or unintended movement․ Designed for outdoor-rated applications, the blade stop provides an additional layer of protection against environmental and operational stress․ It is highly recommended for installations requiring maximum security and durability, ensuring the electric strike functions reliably in demanding conditions․ The blade stop integrates seamlessly with the HES 9400, maintaining its sleek and professional appearance․

8․3 Plug-In Connector for Easy Wiring

The HES 9400 Electric Strike features a Plug-In Connector that simplifies the wiring process, ensuring quick and efficient electrical connections․ This connector is designed to minimize labor and reduce the risk of wiring errors․ It allows for seamless integration with the electric strike, making installation faster and more straightforward․ The Plug-In Connector is particularly useful for outdoor-rated applications, where secure and reliable connections are critical․ This accessory enhances the overall installation experience, providing a secure and efficient wiring solution for the HES 9400 Electric Strike․

Comparison with Other HES Models

The HES 9400 stands out among other HES models like the 9500, 9600, and 9700, offering unique features such as field-selectable operation modes and versatile voltage options․

9․1 HES 9400 vs․ HES 9500

The HES 9400 and HES 9500 share similarities but differ in key features․ The 9400 is designed for lighter applications, offering a compact design, while the 9500 is built for heavier use, providing enhanced durability․ Both models support 12VDC and 24VDC operation and are compatible with rim exit devices․ The 9400 includes a smooth cover for aesthetics, whereas the 9500 focuses on robust performance․ Choose the 9400 for standard applications and the 9500 for high-traffic environments requiring extra strength and reliability․

9․2 HES 9400 vs․ HES 9600

The HES 9400 and HES 9600 differ in advanced features and application suitability․ The 9400 is ideal for standard commercial applications, offering a cost-effective solution with field-selectable operation modes․ In contrast, the 9600 is designed for high-security environments, featuring enhanced monitoring capabilities and superior durability․ While both models support 12VDC and 24VDC, the 9600 includes additional options like latchbolt strike monitoring, making it better suited for specialized or high-security installations requiring advanced functionality and reliability․

9․3 HES 9400 vs․ HES 9700

The HES 9400 and HES 9700 cater to different needs in door security systems․ The 9400 is a cost-effective, surface-mounted electric strike ideal for standard commercial applications, while the 9700 offers advanced features like latchbolt strike monitoring and higher durability for demanding environments․ Both models share field-selectable operation modes and voltage options (12VDC and 24VDC), but the 9700 is designed for applications requiring enhanced security and monitoring capabilities, making it a better choice for high-security installations․

The HES 9400 Electric Strike combines superior performance, adaptability, and reliability, making it a top choice for commercial door security applications, ensuring long-term durability and convenience․

10․1 Summary of Key Features

The HES 9400 Electric Strike is a high-performance, surface-mounted solution designed for rim exit devices, offering field-selectable fail-safe/fail-secure operation and dual voltage options (12VDC/24VDC)․ It includes a 1/8 spacer plate for door gap adjustments and is compatible with 1/2 Pullman latchbolts․ Durable construction and sleek design ensure long-lasting reliability, while its easy installation requires no frame cutting, making it suitable for both metal and wood door frames․ It exceeds Grade 1 standards, providing superior strength and quiet operation for secure and efficient door control systems․

10․2 Final Thoughts on the HES 9400 Electric Strike

The HES 9400 Electric Strike stands out as a reliable and versatile solution for door security systems, combining durability with ease of installation․ Its field-selectable operation modes and voltage options make it adaptable to various applications, while its sleek design enhances aesthetics․ Designed to exceed Grade 1 standards, it ensures superior strength and performance․ Ideal for both commercial and high-security environments, the HES 9400 is a cost-effective choice that delivers quiet, efficient operation and long-term reliability, making it a top recommendation for modern access control needs․

Leave a Reply